Re: cdh4 HA fencing fails when the other node is downHarsh J 2013-01-24, 04:07
Hi Sagar,
Moving the discussion to [EMAIL PROTECTED] as you're asking a CDH specific question here. List can be subscribed at https://groups.google.com/a/cloudera.org/forum/?fromgroups=#!forum/cdh-user. Please take a look at the discussion at https://groups.google.com/a/cloudera.org/d/topic/cdh-user/l21m7gzQYb0/discussion and Todd's specific reply there on why a simple fencer won't work for all scenarios. Using QJM only complements use of ZKFC for Automatic Failover, does not replace it. QJM is a storage method, while ZKFC continues to be used for the actual failover-control. On Thu, Jan 24, 2013 at 7:05 AM, S Naik <[EMAIL PROTECTED]> wrote: > Hi, > > I am trying to setup HA Namenode using cdh4, zkfc. > It works great when I kill -9 the active namenode. > But if I reboot/shutdown the host with active namenode. Failover fails. > > The ZKFC complains fencing not succesful. > It has no route to host exception. > > Is this expected ? > > I looked into mailing list. > It seems that the fix is to move away from zkfc and use quorum based > auto failover. > > But, this should be a pretty common requirement and I would think > there will be a solution for this scenario (With zkfc). > > Please guide me/point me to solution. > > > -Sagar -- Harsh J |