HBase, mail # user - MemStoreFlusher: region has too many store files (client timeout)


+
kzurek 2013-02-04, 12:45
+
Kevin Odell 2013-02-04, 14:46
+
kzurek 2013-02-05, 08:39
Copy link to this message
-
Re: MemStoreFlusher: region has too many store files (client timeout)
Kevin O'dell 2013-02-05, 14:20
kzurek,

  Okay, that is a fair flush size(I have not seen larger than 256MB).  Do
you think you could send me a RS log from yesterday while you were seeing
this issue?  I would just like to thumb through it and make some tuning
recommendations.  I have a pretty good idea of what you need to do, if you
look at:

http://gbif.blogspot.com/2012/07/optimizing-writes-in-hbase.html The
article has some good ideas for write tuning.

On Tue, Feb 5, 2013 at 3:39 AM, kzurek <[EMAIL PROTECTED]> wrote:

> Thanks for the reply, although I should clear some misunderstandings. In
> general, I do know general behavior and difference between minor and major
> compaction, as well as when minor compaction might become (could be
> promoted) to major compaction. I just wanted to verify influence of
> compaction (mostly major) on our cluster performance. Thus, I've created
> test where I'm putting data to only one region (total 71) by one single
> threaded client using build in caching mechanism (according to "HBase The
> Definitive Guide" book) and triggering major compaction by hand
> (HBaseAdmin). Although, after few tests I've noticed that major compaction
> (Large Compaction) is being triggered (cache flusher, recursive queue) so I
> left it as it was (not triggering it anymore). That brought me to this
> situation, where I'm putting data and after a while I'm getting timeouts on
> the client, in meanwhile I see that memstore is being flush which cant
> create new store file (cause there are to many of them) and which is
> frequently blocked by compaction process. I hope that this short
> description
> will bring closer look at the issue. In addition, here are some answers to
> your questions:
>
> 1. How often are you flushing?
>  I'm not triggering flushing by hand, but I've noticed that data is being
> flushed every 4s (275m) or 1m 30s-40s (1.5g).
> 2. How often are you force flushing from HLog rolls?
> Default settings are: blocksize=64 MB, rollsize=60.8 MB, enabled=true,
> optionallogflushinternal=1000ms. It seems that roll is made every hour.
> 3. What size are your flushes?
>  Depends, from 275m up to 1.5g. I've set my memstore flush size to 256m and
> memstore block multiplier to 6. Should I increase the flush size??
> 4. What does your region count look like as that can affect your flush
> size?
> Initial split is 37 regions on 6 RegionServers, but at the moment there are
> 71 regions.
>
>
>
> Kevin O'dell wrote
> > Kzurek,
> >
> > Just because you turn off time based major compactions, it does not mean
> > that you have turned major compaction off.  Compaction can still be
> > promoted to be Majors.  Also, the only real difference between a major
> and
> > minor compaction is one processes deletes.  You should really schedule at
> > least daily major compactions.  As for your blocking issue, there are
> > quite
> > a few things you would want to look at:
> >
> > How often are you flushing?
> >
> > How often are you force flushing from HLog rolls?
> >
> > What size are your flushes?
> >
> > What does your region count look like as that can affect your flush size?
> >
> > etc
> >
> > When I see HBase blocking constantly it is usually a sign that you need
> to
> > do some fine grain tuning.
> >
> > On Mon, Feb 4, 2013 at 7:45 AM, kzurek <
>
> > kzurek@
>
> > > wrote:
> >
> >> I'm facing some issues regarding to major compaction. I've disabled
> major
> >> compaction and it is not triggered manually, but when I'm loading data
> to
> >> selected region, I saw that major compaction queue is growing and it is
> >> being triggered ('Large Compaction' in logs) quite often (mainly due to
> >> cacheFlusher). Moreover, I've noticed that my clients app gets timeout
> >> while
> >> putting data into the cluster (happens when memory store flusher is
> >> trying
> >> to dump memory content to store file, but it cannot due to too many
> store
> >> files), also drop in data rate, which in this case is obvious, is
> >> noticeable.  For me, it looks like compaction process is not fast enough

Kevin O'Dell
Customer Operations Engineer, Cloudera
+
kzurek 2013-02-05, 14:52